Fiberglass (FRP) RO Membrane Vessels by AQUALITEK
Fiberglass (FRP) RO Membrane Vessel — AQUALITEK Reliable Solutions
Durable FRP Construction
AQUALITEK Fiberglass (FRP) RO Membrane Vessels are engineered from advanced composite materials to provide exceptional corrosion resistance, lightweight handling, and long service life. The FRP shell resists chemical attack and environmental degradation, making these vessels ideal for brackish, sea water, and aggressive pretreatment environments. The robust construction ensures stable performance across temperature and pressure variations.
Optimized for RO Performance
Designed specifically for reverse osmosis membrane elements, our FRP RO Membrane Vessel lineup ensures accurate alignment, minimal flow restriction, and secure end-cap sealing. Compatibility with common element sizes (including 4, 8 and industrial housings) means easy integration into new systems or retrofits. Each vessel is optimized to maintain membrane integrity and maximize permeate yield for residential, commercial, and industrial RO plants.
Customizable Configurations
AQUALITEK offers customizable Fiberglass (FRP) RO Membrane Vessel options including single- and multi-element housings, various end-cap types (threaded, flanged), and bespoke length/diameter combinations. Our engineering team works with customers to match pressure ratings, connector styles, and surface linings to suit application requirements—delivering cost-effective, fit-for-purpose solutions.
Applications & Benefits
Ideal for municipal, industrial process water, desalination, and commercial bottled water facilities, FRP RO membrane vessels offer high strength-to-weight ratios, low maintenance, and improved lifecycle economics. Benefits include reduced corrosion maintenance, easier installation, and consistent RO throughput, helping operators achieve lower total cost of ownership and higher system uptime.
Quality Assurance & Support
As a trusted manufacturer headquartered in Guangzhou, Aqualitek Water Treatment Technologies Co., Ltd. (AQT) combines manufacturing excellence with rigorous quality control and global support. Backed by engineering expertise and responsive service, AQUALITEK delivers reliable Fiberglass (FRP) RO Membrane Vessels and end-to-end system solutions to meet diverse water treatment needs worldwide.
Fiberglass (FRP) RO Membrane Vessel Display
What industries does AQT serve?
We provide water treatment solutions for a wide range of industries, including:
1. Industrial Manufacturing – Process water treatment, cooling water, and boiler feed.
2. Hospitality & Commercial – Hotels, restaurants, and office buildings.
3. Residential Applications – Drinking water purification and softening.
4. Healthcare & Pharmaceuticals – Ultra-pure water for laboratories and hospitals.
5. Municipal & Public Utilities – Water supply and wastewater treatment.
6. Food & Beverage Processing – Filtration for beverage p
Is softened water safe to drink?
Yes, but those on low-sodium diets should consider potassium-based softeners or install a separate drinking water filter.
Can ion exchange work with seawater or high-TDS water?
Ion exchange is more suitable for low to moderate TDS water. High-TDS applications often use RO as a primary treatment.
What types of water treatment systems does AQT offer?
AQT provides a wide range of water purification solutions, including reverse osmosis (RO) systems, ultrafiltration (UF) systems, nanofiltration (NF) systems, deionization (DI) systems, electro-deionization (EDI) systems, chemical dosing systems, and water softeners. We also supply spare parts and components for water treatment systems.
What is the difference between softening and deionization?
Softening removes only hardness ions (Ca²⁺, Mg²⁺), while deionization removes both cations and anions to produce high-purity water.
500 LPH Reverse Osmosis (RO) Water Purification Machine TWV - 412
500 LPH Reverse Osmosis (RO) Water Purification Machine TWV - 412
500 liters per hour multi-stage water filtration and softening system
500 liters per hour multi-stage water filtration and softening system
20 TPH Uninterrupted(1 Working + 1 Standby) Ultrafiltration System
20 TPH Uninterrupted(1 Working + 1 Standby) Ultrafiltration System
1000LPH UF System Industrial-Grade Water Purification Plant
1000LPH UF System Industrial-Grade Water Purification Plant
4TPH Industrial Reverse Osmosis Water Purification RO System
4TPH Industrial Reverse Osmosis Water Purification RO System
500 liters per hour multi-stage water filtration and softening system
500 liters per hour multi-stage water filtration and softening system
20 TPH Uninterrupted(1 Working + 1 Standby) Ultrafiltration System
20 TPH Uninterrupted(1 Working + 1 Standby) Ultrafiltration System
1000LPH UF System Industrial-Grade Water Purification Plant
1000LPH UF System Industrial-Grade Water Purification Plant
4TPH Industrial Reverse Osmosis Water Purification RO System
4TPH Industrial Reverse Osmosis Water Purification RO System
RUNXIN Automatic Filter/Softener Industrial Control Valve
RUNXIN Automatic Filter/Softener Industrial Control Valve
12TPH Industrial UF Water Treatment Device with High Throughput
12TPH Industrial UF Water Treatment Device with High Throughput
250LPH Portable Seawater Desalination Machine Compact RO Water Maker
250LPH Portable Seawater Desalination Machine Compact RO Water Maker
Runxin Manual Filter Control Valves for filter tanks
Runxin Manual Filter Control Valves for filter tanks
Two Bed Ion Exchange Deionizer for Industrial, Laboratory, and Boiler Feed Water Purification
Two Bed Ion Exchange Deionizer for Industrial, Laboratory, and Boiler Feed Water Purification
High-Purity Manganese Sand for Iron & Manganese Removal Water Filtration
High-Purity Manganese Sand for Iron & Manganese Removal Water FiltrationBest Guide: How to Control Bacterial Growth in an RO System| Insights by AQUALITEK
Learn how to effectively control bacterial growth in reverse osmosis (RO) systems through optimized pretreatment, disinfection methods, system design, and regular maintenance. Prevent biofouling, improve water quality, and extend membrane lifespan with proven industrial strategies.
Best Guide: Why Scale Inhibitors Are Essential in RO Systems| Insights by AQUALITEK
Learn why scale inhibitors are crucial in reverse osmosis (RO) systems, how they prevent scaling, extend membrane lifespan, and improve system efficiency. Understand their working principles, types, and correct dosing methods for industrial water treatment applications.
Best Guide: Main Types of RO Membrane Clogging and Their Solutions| Insights by AQUALITEK
RO (Reverse Osmosis) membrane clogging is one of the most critical issues affecting water treatment system performance. Over time, contaminants in feedwater can accumulate on the membrane surface, reducing flux, increasing operating pressure, and compromising product water quality. This article explores the main types of RO membrane clogging, their causes, identifying symptoms, and effective solutions to maintain long-term system performance.
Best Guide: The Most Common Operational Problems in Industrial RO Systems and How to Solve Them| Insights by AQUALITEK
Learn about the most common operational problems in industrial reverse osmosis (RO) systems—including fouling, scaling, biofouling, and pressure fluctuations. Discover expert insights into causes, prevention, and maintenance strategies to ensure stable water quality and long-term system efficiency.
Request More Products Information
Submit your inquiry now to receive detailed specifications, pricing, and tailored solutions from our professional team.
Rest assured that your privacy is important to us, and all information provided will be handled with the utmost confidentiality.
Copyright © 2025 AQUALITEK. All rights reserved.
AQT
AQT