20 TPH Ultrafiltration Water Treatment Plant — AQUALITEK Category
20 TPH Ultrafiltration Water Treatment Plant — High-Capacity UF Solutions
Overview
The 20 TPH Ultrafiltration Water Treatment Plant from AQUALITEK is a robust, factory-tested solution designed to produce up to 20 tons per hour of high-quality permeate using membrane ultrafiltration technology. Ideal for industrial processes, commercial facilities, and municipal pre-treatment, this system combines proven engineering with modular design for fast deployment and reliable operation.
Key Features
Our 20 TPH Ultrafiltration Water Treatment Plant features durable hollow-fiber/polymer membranes, automated backwash and air scouring, PLC control with remote monitoring, energy-efficient pumps, and compact skid-mounted units for simplified site installation. Built for low fouling and long membrane life, the system minimizes downtime and reduces lifecycle cost.
Technical Advantages
Engineered by AQUALITEK’s experienced R&D team, the plant delivers consistent turbidity removal, bacteria and colloid retention, and predictable flux rates. Intelligent control algorithms optimize TMP and cleaning cycles, while scalable arrays allow seamless capacity expansion or redundancy for critical operations.
Applications
Suitable for pre-treatment to RO, potable water production, boiler feed, food & beverage, pharmaceuticals, and wastewater reuse, the 20 TPH Ultrafiltration Water Treatment Plant adapts to varied feed qualities and regulatory demands. It is particularly effective where consistent microbiological control and particle removal are required.
Customization & Integration
AQUALITEK provides customizable skids, pretreatment options (multimedia filters, chemical dosing), and post-treatment modules. Our engineers tailor controls, footprint, and material selections to match site conditions, minimizing civil works and commissioning time.
Service, Warranty & Support
We offer global commissioning, operator training, preventative maintenance packages, and genuine spare parts. AQUALITEK’s service network ensures rapid response and long-term performance backed by comprehensive warranties and performance guarantees.
Sustainability & ROI
Optimized for low energy use and minimal chemical consumption, the 20 TPH Ultrafiltration Water Treatment Plant reduces operational cost and environmental footprint while improving water recovery rates—delivering measurable ROI for capital and operational budgets.
Next Steps
Contact AQUALITEK to discuss site assessment, pilot testing, and a tailored proposal. Our specialists will help you select the ideal configuration of the 20 TPH Ultrafiltration Water Treatment Plant to meet capacity, quality, and budget goals.
20 TPH Ultrafiltration Water Treatment Plant Display
Can I automate the filter cleaning process?
Absolutely. Our automatic backwash filters come with timer-based or differential pressure-triggered controls.
Does AQT provide technical support and after-sales service?
Yes! We offer comprehensive technical support, including installation guidance, troubleshooting, spare parts supply, and ongoing maintenance assistance. Our after-sales team is available to ensure your water treatment system operates efficiently.
Can I use a water softener with a septic system?
Yes. Studies show no negative impact, especially when using metered regeneration systems.
What is the difference between Reverse Osmosis (RO), Ultrafiltration (UF), and Nanofiltration (NF)?
1. Reverse Osmosis (RO): Removes up to 99.9% of contaminants, including salts, bacteria, viruses, and heavy metals.
2. Ultrafiltration (UF): Uses a membrane filtration process to remove bacteria and particles, while retaining essential minerals.
3. Nanofiltration (NF): Falls between RO and UF, removing some salts and organic compounds while allowing certain minerals to pass through.
500 liters per hour multi-stage water filtration and softening system
500 liters per hour multi-stage water filtration and softening system
20 TPH Uninterrupted(1 Working + 1 Standby) Ultrafiltration System
20 TPH Uninterrupted(1 Working + 1 Standby) Ultrafiltration System
1000LPH UF System Industrial-Grade Water Purification Plant
1000LPH UF System Industrial-Grade Water Purification Plant
4TPH Industrial Reverse Osmosis Water Purification RO System
4TPH Industrial Reverse Osmosis Water Purification RO System
RUNXIN Automatic Filter/Softener Industrial Control Valve
RUNXIN Automatic Filter/Softener Industrial Control Valve
500 liters per hour multi-stage water filtration and softening system
500 liters per hour multi-stage water filtration and softening system
20 TPH Uninterrupted(1 Working + 1 Standby) Ultrafiltration System
20 TPH Uninterrupted(1 Working + 1 Standby) Ultrafiltration System
1000LPH UF System Industrial-Grade Water Purification Plant
1000LPH UF System Industrial-Grade Water Purification Plant
4TPH Industrial Reverse Osmosis Water Purification RO System
4TPH Industrial Reverse Osmosis Water Purification RO System
RUNXIN Automatic Filter/Softener Industrial Control Valve
RUNXIN Automatic Filter/Softener Industrial Control Valve
12TPH Industrial UF Water Treatment Device with High Throughput
12TPH Industrial UF Water Treatment Device with High Throughput
250LPH Portable Seawater Desalination Machine Compact RO Water Maker
250LPH Portable Seawater Desalination Machine Compact RO Water Maker
Runxin Manual Filter Control Valves for filter tanks
Runxin Manual Filter Control Valves for filter tanks
Two Bed Ion Exchange Deionizer for Industrial, Laboratory, and Boiler Feed Water Purification
Two Bed Ion Exchange Deionizer for Industrial, Laboratory, and Boiler Feed Water Purification
High-Purity Manganese Sand for Iron & Manganese Removal Water Filtration
High-Purity Manganese Sand for Iron & Manganese Removal Water FiltrationUsed RO Membrane Utilization: Practical and Responsible Uses for Replaced Old Membrane Elements| Insights by AQUALITEK
Replaced RO membranes are not always waste. This Best-practice article explores feasible reuse scenarios, limitations, environmental considerations, and compliant disposal options for used RO membrane elements.
Besides Valve Adjustment, What Other Factors Affect the Actual Recovery Rate of an RO System?| Insights by AQUALITEK
RO system recovery rate is not determined by valve adjustment alone. This Best-practice article explains all key factors that influence actual recovery, including feed water quality, temperature, membrane condition, pressure balance, fouling, and system design.
Why Can RO Permeate Still Contain Excessive Bacteria Even Though RO Membranes Trap Bacteria?| Insights by AQUALITEK
RO membranes can physically reject bacteria, yet permeate bacterial counts may still exceed limits. This Best-practice article explains the real causes, risks, and proven control measures in industrial and commercial RO systems.
Can RO Membrane Surfaces Be Manually Cleaned Using Physical Methods Like Brushing?| Insights by AQUALITEK
Manually cleaning RO membranes with brushes or physical tools is a common misconception. This Best-practice guide explains why physical cleaning damages membranes, what irreversible risks it causes, and the correct alternatives for membrane cleaning.
Request More Products Information
Submit your inquiry now to receive detailed specifications, pricing, and tailored solutions from our professional team.
Rest assured that your privacy is important to us, and all information provided will be handled with the utmost confidentiality.
Copyright © 2025 AQUALITEK. All rights reserved.
AQT
AQT