AQUALITEK Ultrafiltration (UF) System for Drinking Water Treatment
AQUALITEK Ultrafiltration (UF) System for Drinking Water Treatment
Overview
AQUALITEK's ultrafiltration (UF) system for drinking water treatment is engineered to provide high-quality, safe water across households, commercial properties and industrial sites. Combining robust UF membrane technology with modular system design, our solutions remove turbidity, bacteria, and colloids while preserving essential minerals and minimizing chemical use.
Performance and Reliability
Designed with durable hollow-fiber membranes and intelligent control modules, the UF system ensures consistent permeate quality and stable flux rates. Advanced backwash and air scouring reduce fouling, extend membrane life and lower operational costs, delivering reliable performance even on variable feedwater sources.
Energy Efficiency and Low Maintenance
AQUALITEK ultrafiltration systems are optimized for low energy consumption through efficient pumps and smart PLC control. Predictive maintenance alerts and easy-access components simplify routine servicing and reduce downtime, making UF ideal for projects that require cost-effective, continuous operation.
Scalable Modular Design
Whether the requirement is a point-of-entry residential unit or a multi-stage industrial plant, our modular approach lets you scale capacity quickly. Pre-engineered skids and containerized options accelerate deployment while maintaining stringent quality control and consistent performance.
Compliance and Water Safety
Our UF systems comply with international drinking water standards and are suited for pretreatment ahead of disinfection or RO polishing. By providing a reliable barrier to pathogens and suspended solids, AQUALITEK supports safe, regulatory-compliant water supply strategies.
Why Choose AQUALITEK
As a Guangzhou-based leader in water treatment technologies, AQUALITEK combines engineering expertise, manufacturing excellence and global service support. We deliver tailored UF solutions that balance performance, sustainability and lifecycle cost, ensuring access to clean water where it matters most.
Get Started
Contact AQUALITEK to assess your water needs and explore our ultrafiltration (UF) system options. Our team will recommend the optimal configuration for reliability, operational efficiency and long-term value.
ultrafiltration (UF) system for drinking water treatment Display
Can your membrane systems treat seawater?
Yes. Our seawater RO systems are designed to handle high salinity with corrosion-resistant materials and energy recovery devices.
Can I automate the filter cleaning process?
Absolutely. Our automatic backwash filters come with timer-based or differential pressure-triggered controls.
Which chemicals are required for regeneration?
Softening uses NaCl. Demineralization uses HCl or H₂SO₄ for cation resin and NaOH for anion resin.
How do I choose the right water treatment system for my needs?
The choice depends on factors such as water quality, application, flow rate, and purification requirements. Our team of experts can analyze your water source and recommend the most suitable solution for residential, commercial, or industrial applications.
How often should I replace filters and membranes?
Filter and membrane lifespan depends on water quality, usage, and system type. General guidelines:
1. Sediment & Carbon Filters: Replace every 6–12 months.
2. RO Membranes: Replace every 2–3 years, depending on water conditions.
3. UF/NF Membranes: Replace every 1–2 years.
Regular maintenance ensures optimal performance and water quality.
500 LPH Reverse Osmosis (RO) Water Purification Machine TWV - 412
500 LPH Reverse Osmosis (RO) Water Purification Machine TWV - 412
500 liters per hour multi-stage water filtration and softening system
500 liters per hour multi-stage water filtration and softening system
20 TPH Uninterrupted(1 Working + 1 Standby) Ultrafiltration System
20 TPH Uninterrupted(1 Working + 1 Standby) Ultrafiltration System
1000LPH UF System Industrial-Grade Water Purification Plant
1000LPH UF System Industrial-Grade Water Purification Plant
4TPH Industrial Reverse Osmosis Water Purification RO System
4TPH Industrial Reverse Osmosis Water Purification RO System
500 liters per hour multi-stage water filtration and softening system
500 liters per hour multi-stage water filtration and softening system
20 TPH Uninterrupted(1 Working + 1 Standby) Ultrafiltration System
20 TPH Uninterrupted(1 Working + 1 Standby) Ultrafiltration System
1000LPH UF System Industrial-Grade Water Purification Plant
1000LPH UF System Industrial-Grade Water Purification Plant
4TPH Industrial Reverse Osmosis Water Purification RO System
4TPH Industrial Reverse Osmosis Water Purification RO System
RUNXIN Automatic Filter/Softener Industrial Control Valve
RUNXIN Automatic Filter/Softener Industrial Control Valve
12TPH Industrial UF Water Treatment Device with High Throughput
12TPH Industrial UF Water Treatment Device with High Throughput
250LPH Portable Seawater Desalination Machine Compact RO Water Maker
250LPH Portable Seawater Desalination Machine Compact RO Water Maker
Runxin Manual Filter Control Valves for filter tanks
Runxin Manual Filter Control Valves for filter tanks
Two Bed Ion Exchange Deionizer for Industrial, Laboratory, and Boiler Feed Water Purification
Two Bed Ion Exchange Deionizer for Industrial, Laboratory, and Boiler Feed Water Purification
High-Purity Manganese Sand for Iron & Manganese Removal Water Filtration
High-Purity Manganese Sand for Iron & Manganese Removal Water FiltrationBest Guide: Main Types of RO Membrane Clogging and Their Solutions| Insights by AQUALITEK
RO (Reverse Osmosis) membrane clogging is one of the most critical issues affecting water treatment system performance. Over time, contaminants in feedwater can accumulate on the membrane surface, reducing flux, increasing operating pressure, and compromising product water quality. This article explores the main types of RO membrane clogging, their causes, identifying symptoms, and effective solutions to maintain long-term system performance.
Best Guide: The Most Common Operational Problems in Industrial RO Systems and How to Solve Them| Insights by AQUALITEK
Learn about the most common operational problems in industrial reverse osmosis (RO) systems—including fouling, scaling, biofouling, and pressure fluctuations. Discover expert insights into causes, prevention, and maintenance strategies to ensure stable water quality and long-term system efficiency.
Best Guide: Why Industrial RO Systems Require Strict Pretreatment Processes| Insights by AQUALITEK
Pretreatment is the foundation of any industrial reverse osmosis (RO) system. Without a robust pretreatment process, even the most advanced membranes and control systems cannot perform efficiently. This article explains why strict pretreatment is critical, what contaminants it targets, and how it impacts membrane performance, operational stability, and total lifecycle cost.
Best Technical Overview: Main Components of an Industrial RO System| Insights by AQUALITEK
An industrial reverse osmosis (RO) system is composed of multiple interdependent components that work together to purify water efficiently and reliably. This article provides a comprehensive breakdown of the main components in an RO system, explaining their functions, design considerations, and how they contribute to system performance and longevity.
Request More Products Information
Submit your inquiry now to receive detailed specifications, pricing, and tailored solutions from our professional team.
Rest assured that your privacy is important to us, and all information provided will be handled with the utmost confidentiality.
Copyright © 2025 AQUALITEK. All rights reserved.
AQT
AQT