4TPH High-Efficiency RO Water Treatment System for Electronic Component Cleaning Water Use
4TPH High-Efficiency RO Water Treatment System for Electronic Component Cleaning Water Use
Designed for electronic manufacturing where consistency and purity matter, AQUALITEK’s 4TPH High-Efficiency RO Water Treatment System for Electronic Component Cleaning Water Use provides a dependable source of low-TDS, low-organic water. Built on proven reverse osmosis technology with precision pretreatment and post-treatment polishing, this system supports repeatable cleaning outcomes and minimizes defects.
Key Features
Our system integrates multistage pretreatment (sand/activated carbon/antiscalant dosing), high-rejection RO membranes, and optional ultrafiltration or electrodeionization. Intelligent PLC control, real-time conductivity/TDS monitoring, and automated flushing ensure high recovery, membrane protection, and stable output water quality tailored to cleaning chemistries.
Typical Applications
Optimized for rinsing and precision cleaning of PCBs, SMT components, and semiconductor assembly, the 4TPH system is ideal for electronics fabs, contract manufacturers, and cleaning service providers seeking reliable process water meeting stringent contaminant limits.
Technical Highlights
Output capacity: 4 TPH (approx. 16 m3/day). Typical product water TDS < 10 ppm (configurable), recovery rates up to 75% with recovery-enhancing options, modular skid-mounted design for easy installation, and compact footprint for cleanroom-friendly deployment.
Operational Benefits
Lower chemical usage and rework rates thanks to consistent water purity. Energy-efficient pumps and optimized membrane spacing reduce operating costs. Automated controls minimize manual intervention and support continuous production with predictable performance.
Customization & Support
AQUALITEK offers turn-key solutions: system sizing, material compatibility assessment, integration with DI loops, and comprehensive commissioning. Local technical support, spare parts, and preventive maintenance packages ensure uptime and long membrane life.
Sustainability & ROI
High recovery options and wastewater minimization lower disposal costs. Durable components and efficient operation deliver fast payback through reduced chemical, water, and maintenance expenses—aligning quality assurance with environmental responsibility.
Why Choose AQUALITEK
Headquartered in Guangzhou, AQT (AQUALITEK) combines engineering expertise and manufacturing excellence to provide certified, reliable RO systems. For consultations, demos, or customized quotations, contact our specialists to optimize your electronic component cleaning water supply.
4TPH High-Efficiency RO Water Treatment System for Electronic Component Cleaning Water Use Display
Do you offer plug-and-play solutions?
Absolutely. We offer containerized membrane systems that are factory-tested, compact, and quick to deploy.
Can I use a water softener with a septic system?
Yes. Studies show no negative impact, especially when using metered regeneration systems.
Is softened water safe to drink?
Yes, but those on low-sodium diets should consider potassium-based softeners or install a separate drinking water filter.
What is the difference between Reverse Osmosis (RO), Ultrafiltration (UF), and Nanofiltration (NF)?
1. Reverse Osmosis (RO): Removes up to 99.9% of contaminants, including salts, bacteria, viruses, and heavy metals.
2. Ultrafiltration (UF): Uses a membrane filtration process to remove bacteria and particles, while retaining essential minerals.
3. Nanofiltration (NF): Falls between RO and UF, removing some salts and organic compounds while allowing certain minerals to pass through.
500 LPH Reverse Osmosis (RO) Water Purification Machine TWV - 412
500 LPH Reverse Osmosis (RO) Water Purification Machine TWV - 412
500 liters per hour multi-stage water filtration and softening system
500 liters per hour multi-stage water filtration and softening system
20 TPH Uninterrupted(1 Working + 1 Standby) Ultrafiltration System
20 TPH Uninterrupted(1 Working + 1 Standby) Ultrafiltration System
1000LPH UF System Industrial-Grade Water Purification Plant
1000LPH UF System Industrial-Grade Water Purification Plant
RUNXIN Automatic Filter/Softener Industrial Control Valve
RUNXIN Automatic Filter/Softener Industrial Control Valve
500 liters per hour multi-stage water filtration and softening system
500 liters per hour multi-stage water filtration and softening system
20 TPH Uninterrupted(1 Working + 1 Standby) Ultrafiltration System
20 TPH Uninterrupted(1 Working + 1 Standby) Ultrafiltration System
1000LPH UF System Industrial-Grade Water Purification Plant
1000LPH UF System Industrial-Grade Water Purification Plant
4TPH Industrial Reverse Osmosis Water Purification RO System
4TPH Industrial Reverse Osmosis Water Purification RO System
RUNXIN Automatic Filter/Softener Industrial Control Valve
RUNXIN Automatic Filter/Softener Industrial Control Valve
12TPH Industrial UF Water Treatment Device with High Throughput
12TPH Industrial UF Water Treatment Device with High Throughput
250LPH Portable Seawater Desalination Machine Compact RO Water Maker
250LPH Portable Seawater Desalination Machine Compact RO Water Maker
Runxin Manual Filter Control Valves for filter tanks
Runxin Manual Filter Control Valves for filter tanks
Two Bed Ion Exchange Deionizer for Industrial, Laboratory, and Boiler Feed Water Purification
Two Bed Ion Exchange Deionizer for Industrial, Laboratory, and Boiler Feed Water Purification
High-Purity Manganese Sand for Iron & Manganese Removal Water Filtration
High-Purity Manganese Sand for Iron & Manganese Removal Water FiltrationBest Guide: Why Scale Inhibitors Are Essential in RO Systems| Insights by AQUALITEK
Learn why scale inhibitors are crucial in reverse osmosis (RO) systems, how they prevent scaling, extend membrane lifespan, and improve system efficiency. Understand their working principles, types, and correct dosing methods for industrial water treatment applications.
Best Guide: Main Types of RO Membrane Clogging and Their Solutions| Insights by AQUALITEK
RO (Reverse Osmosis) membrane clogging is one of the most critical issues affecting water treatment system performance. Over time, contaminants in feedwater can accumulate on the membrane surface, reducing flux, increasing operating pressure, and compromising product water quality. This article explores the main types of RO membrane clogging, their causes, identifying symptoms, and effective solutions to maintain long-term system performance.
Best Guide: The Most Common Operational Problems in Industrial RO Systems and How to Solve Them| Insights by AQUALITEK
Learn about the most common operational problems in industrial reverse osmosis (RO) systems—including fouling, scaling, biofouling, and pressure fluctuations. Discover expert insights into causes, prevention, and maintenance strategies to ensure stable water quality and long-term system efficiency.
Best Guide: Why Industrial RO Systems Require Strict Pretreatment Processes| Insights by AQUALITEK
Pretreatment is the foundation of any industrial reverse osmosis (RO) system. Without a robust pretreatment process, even the most advanced membranes and control systems cannot perform efficiently. This article explains why strict pretreatment is critical, what contaminants it targets, and how it impacts membrane performance, operational stability, and total lifecycle cost.
Request More Products Information
Submit your inquiry now to receive detailed specifications, pricing, and tailored solutions from our professional team.
Rest assured that your privacy is important to us, and all information provided will be handled with the utmost confidentiality.
Copyright © 2025 AQUALITEK. All rights reserved.
AQT
AQT