4TPH Industrial Grade RO Water Treatment Plant – AQUALITEK Commercial Reverse Osmosis Filtration System
4TPH Industrial Grade RO Water Treatment Plant Commercial Reverse Osmosis Filtration System
Overview
AQUALITEK’s 4TPH Industrial Grade RO Water Treatment Plant Commercial Reverse Osmosis Filtration System is designed to produce up to 4 tonnes per hour of high-purity water for industrial, commercial and institutional applications. Built by Aqualitek Water Treatment Technologies Co., Ltd. in Guangzhou, China, this system integrates proven RO membranes, precision pumps, and robust control systems to ensure consistent water quality and dependable uptime.
Key Features
Our 4TPH RO unit features multi-stage pretreatment (media filtration, activated carbon, anti-scalant dosing), high-efficiency low-pressure RO membranes, energy-saving pumps, and PLC-based automation with remote monitoring. Corrosion-resistant skid design, quick-change cartridge housings, and modular racks simplify maintenance and scale expansion.
Technical Advantages
Engineered for performance, the plant offers stable recovery rates, superior salt rejection, and optimized flux to extend membrane life. Integrated sensors and automatic backwash cycles reduce downtime. Customizable feed pretreatment and concentrate management options (brine discharge, evaporation, or recycle) allow site-specific optimization.
Applications
Ideal for food & beverage, pharmaceuticals, boiler feed, cooling towers, electronics manufacturing, and municipal booster systems, this commercial reverse osmosis filtration system meets diverse industrial water purification demands with consistent output and compliance-ready quality.
Why Choose AQUALITEK
AQUALITEK combines engineering excellence with global manufacturing capacity, delivering tailored, cost-effective solutions. Our systems include full FAT/SAT testing, documentation, and optional containerized or mobile configurations for rapid deployment.
Installation, Service & Support
We provide turnkey services: system design, site survey, installation, commissioning and operator training. Global spare-part availability and preventive maintenance contracts ensure long-term reliability and low lifecycle cost.
Sustainability & ROI
Optimized energy use, high recovery rates and membrane longevity lower operating expenses while reducing waste. The 4TPH RO plant delivers measurable ROI through reduced chemical use, lower downtime and improved process consistency.
Call to Action
Contact AQUALITEK today for a customized proposal, datasheet, and pilot testing options for your 4TPH Industrial Grade RO Water Treatment Plant Commercial Reverse Osmosis Filtration System.
4TPH Industrial Grade RO Water Treatment Plant Commercial Reverse Osmosis Filtration System Display
Can ion exchange work with seawater or high-TDS water?
Ion exchange is more suitable for low to moderate TDS water. High-TDS applications often use RO as a primary treatment.
Can I use a water softener with a septic system?
Yes. Studies show no negative impact, especially when using metered regeneration systems.
How do I know when to add salt to my softener?
Check the brine tank monthly. Modern systems often alert you automatically when salt levels are low.
Can AQT provide custom water treatment solutions?
Yes! We specialize in OEM/ODM water treatment solutions and can design custom filtration systems tailored to your business, industry, or brand requirements. Our team can assist with system design, branding, private labeling, and technical support.
500 LPH Reverse Osmosis (RO) Water Purification Machine TWV - 412
500 LPH Reverse Osmosis (RO) Water Purification Machine TWV - 412
500 liters per hour multi-stage water filtration and softening system
500 liters per hour multi-stage water filtration and softening system
20 TPH Uninterrupted(1 Working + 1 Standby) Ultrafiltration System
20 TPH Uninterrupted(1 Working + 1 Standby) Ultrafiltration System
1000LPH UF System Industrial-Grade Water Purification Plant
1000LPH UF System Industrial-Grade Water Purification Plant
RUNXIN Automatic Filter/Softener Industrial Control Valve
RUNXIN Automatic Filter/Softener Industrial Control Valve
500 liters per hour multi-stage water filtration and softening system
500 liters per hour multi-stage water filtration and softening system
20 TPH Uninterrupted(1 Working + 1 Standby) Ultrafiltration System
20 TPH Uninterrupted(1 Working + 1 Standby) Ultrafiltration System
1000LPH UF System Industrial-Grade Water Purification Plant
1000LPH UF System Industrial-Grade Water Purification Plant
4TPH Industrial Reverse Osmosis Water Purification RO System
4TPH Industrial Reverse Osmosis Water Purification RO System
RUNXIN Automatic Filter/Softener Industrial Control Valve
RUNXIN Automatic Filter/Softener Industrial Control Valve
12TPH Industrial UF Water Treatment Device with High Throughput
12TPH Industrial UF Water Treatment Device with High Throughput
250LPH Portable Seawater Desalination Machine Compact RO Water Maker
250LPH Portable Seawater Desalination Machine Compact RO Water Maker
Runxin Manual Filter Control Valves for filter tanks
Runxin Manual Filter Control Valves for filter tanks
Two Bed Ion Exchange Deionizer for Industrial, Laboratory, and Boiler Feed Water Purification
Two Bed Ion Exchange Deionizer for Industrial, Laboratory, and Boiler Feed Water Purification
High-Purity Manganese Sand for Iron & Manganese Removal Water Filtration
High-Purity Manganese Sand for Iron & Manganese Removal Water FiltrationHow to Confirm That Chemical Cleaning Agents Have Been Completely Rinsed Off in an RO System| Insights by AQUALITEK
Incomplete rinsing after RO chemical cleaning can contaminate permeate water and damage membranes. This Best-practice guide explains reliable methods to confirm that cleaning chemicals have been fully flushed from the system before returning to service.
Slight Water Seepage at Both Ends of the RO Membrane Housing: Is It Serious and How Should It Be Handled?Insights by AQUALITEK
Slight water seepage at both ends of an RO membrane housing is a common issue, but it should never be ignored. This article explains the causes, risks, inspection steps, and correct handling methods to prevent membrane damage and system failure.
The Ultimate Guide to Commercial Reverse Osmosis Systems for 2026
This definitive guide explores Commercial Reverse Osmosis (RO) systems for 2026. It covers the scientific principles of RO, detailed system components, specific industrial applications, and critical selection criteria. Readers will gain insights into maintenance best practices, troubleshooting common issues, and future technological trends, empowering businesses to make data-driven decisions for optimal water quality and ROI.
Using RO Permeate as Cooling Water: Key Precautions You Must Take| Insights by AQUALITEK
Using RO permeate directly as cooling water can improve heat transfer efficiency, but it also introduces corrosion, stability, and biological risks. This guide explains the key precautions, control strategies, and best practices to safely and economically use RO permeate in cooling systems.
Request More Products Information
Submit your inquiry now to receive detailed specifications, pricing, and tailored solutions from our professional team.
Rest assured that your privacy is important to us, and all information provided will be handled with the utmost confidentiality.