Multimedia Filter for Drinking Water Treatment — AQUALITEK Solutions
Multimedia Filter for Drinking Water Treatment — Efficient Pretreatment by AQUALITEK
Key Features
Our multimedia filter for drinking water treatment combines graded layers of anthracite, sand, and garnet to deliver superior particulate removal and long service cycles. Engineered media distribution, low headloss design, and automated backwash options give stable filtration performance and low operational costs, making it ideal for municipal, commercial, and industrial water systems.
Performance Benefits
AQUALITEK multimedia filters reduce turbidity, suspended solids, and organic load upstream of RO, UV, and disinfection units, enhancing overall system reliability. The filters provide consistent effluent quality, extend membrane life, and lower chemical consumption. High flow rates and optimized bed depths ensure minimal footprint without sacrificing filtration efficiency.
Applications
Designed for drinking water treatment, our multimedia filter is suitable for community water supply, hotels, food & beverage plants, hospitals, and residential complexes. It serves as a robust pretreatment or stand-alone polishing unit where removal of visible particles and particulate-bound contaminants is required.
Technical Highlights
Available in fiberglass-reinforced plastic (FRP) and stainless-steel vessels, AQUALITEK filters support custom flow rates, inlet pressures, and automated control packages. Typical specifications include multimodal media beds, programmable backwash, pressure gauges, and optional chemical or air scour for enhanced cleaning cycles.
Why Choose AQUALITEK
With decades of engineering expertise, AQUALITEK delivers reliable, customizable multimedia filter solutions that balance performance and cost. Our commitment to quality manufacturing and global support ensures fast delivery, easy commissioning, and responsive after-sales service.
Installation & Maintenance
Simple skid-mounted designs and modular assemblies allow rapid installation and scale-up. Routine maintenance includes periodic media inspection and scheduled backwash management; AQUALITEK provides training, spare parts, and lifecycle service contracts to maximize uptime.
About AQUALITEK
Aqualitek Water Treatment Technologies Co., Ltd. (AQT) in Guangzhou specializes in advanced water treatment systems and components. We deliver tailored, sustainable solutions for drinking water treatment worldwide—ensuring clean, safe water through innovation and engineering excellence.
How often should I replace filters and membranes?
Filter and membrane lifespan depends on water quality, usage, and system type. General guidelines:
1. Sediment & Carbon Filters: Replace every 6–12 months.
2. RO Membranes: Replace every 2–3 years, depending on water conditions.
3. UF/NF Membranes: Replace every 1–2 years.
Regular maintenance ensures optimal performance and water quality.
Are mixed bed systems better than two-bed systems?
Mixed bed polishers are used for final polishing after RO or two-bed deionization to achieve ultra-pure water.
Can ion exchange work with seawater or high-TDS water?
Ion exchange is more suitable for low to moderate TDS water. High-TDS applications often use RO as a primary treatment.
Are AQT’s water treatment products certified?
Yes! Our products comply with international quality and safety standards, including ISO, CE, and NSF certifications. We prioritize high-quality materials, advanced technology, and strict quality control to ensure superior performance and reliability.
How often is regeneration needed?
It depends on water quality and usage. Most systems regenerate every few days to a week under normal loads.
500 liters per hour multi-stage water filtration and softening system
500 liters per hour multi-stage water filtration and softening system
20 TPH Uninterrupted(1 Working + 1 Standby) Ultrafiltration System
20 TPH Uninterrupted(1 Working + 1 Standby) Ultrafiltration System
1000LPH UF System Industrial-Grade Water Purification Plant
1000LPH UF System Industrial-Grade Water Purification Plant
4TPH Industrial Reverse Osmosis Water Purification RO System
4TPH Industrial Reverse Osmosis Water Purification RO System
RUNXIN Automatic Filter/Softener Industrial Control Valve
RUNXIN Automatic Filter/Softener Industrial Control Valve
500 liters per hour multi-stage water filtration and softening system
500 liters per hour multi-stage water filtration and softening system
20 TPH Uninterrupted(1 Working + 1 Standby) Ultrafiltration System
20 TPH Uninterrupted(1 Working + 1 Standby) Ultrafiltration System
1000LPH UF System Industrial-Grade Water Purification Plant
1000LPH UF System Industrial-Grade Water Purification Plant
4TPH Industrial Reverse Osmosis Water Purification RO System
4TPH Industrial Reverse Osmosis Water Purification RO System
RUNXIN Automatic Filter/Softener Industrial Control Valve
RUNXIN Automatic Filter/Softener Industrial Control Valve
12TPH Industrial UF Water Treatment Device with High Throughput
12TPH Industrial UF Water Treatment Device with High Throughput
250LPH Portable Seawater Desalination Machine Compact RO Water Maker
250LPH Portable Seawater Desalination Machine Compact RO Water Maker
Runxin Manual Filter Control Valves for filter tanks
Runxin Manual Filter Control Valves for filter tanks
Two Bed Ion Exchange Deionizer for Industrial, Laboratory, and Boiler Feed Water Purification
Two Bed Ion Exchange Deionizer for Industrial, Laboratory, and Boiler Feed Water Purification
High-Purity Manganese Sand for Iron & Manganese Removal Water Filtration
High-Purity Manganese Sand for Iron & Manganese Removal Water FiltrationBest Guide: Why Scale Inhibitors Are Essential in RO Systems| Insights by AQUALITEK
Learn why scale inhibitors are crucial in reverse osmosis (RO) systems, how they prevent scaling, extend membrane lifespan, and improve system efficiency. Understand their working principles, types, and correct dosing methods for industrial water treatment applications.
Best Guide: Main Types of RO Membrane Clogging and Their Solutions| Insights by AQUALITEK
RO (Reverse Osmosis) membrane clogging is one of the most critical issues affecting water treatment system performance. Over time, contaminants in feedwater can accumulate on the membrane surface, reducing flux, increasing operating pressure, and compromising product water quality. This article explores the main types of RO membrane clogging, their causes, identifying symptoms, and effective solutions to maintain long-term system performance.
Best Guide: The Most Common Operational Problems in Industrial RO Systems and How to Solve Them| Insights by AQUALITEK
Learn about the most common operational problems in industrial reverse osmosis (RO) systems—including fouling, scaling, biofouling, and pressure fluctuations. Discover expert insights into causes, prevention, and maintenance strategies to ensure stable water quality and long-term system efficiency.
Best Guide: Why Industrial RO Systems Require Strict Pretreatment Processes| Insights by AQUALITEK
Pretreatment is the foundation of any industrial reverse osmosis (RO) system. Without a robust pretreatment process, even the most advanced membranes and control systems cannot perform efficiently. This article explains why strict pretreatment is critical, what contaminants it targets, and how it impacts membrane performance, operational stability, and total lifecycle cost.
Request More Products Information
Submit your inquiry now to receive detailed specifications, pricing, and tailored solutions from our professional team.
Rest assured that your privacy is important to us, and all information provided will be handled with the utmost confidentiality.
Copyright © 2025 AQUALITEK. All rights reserved.
AQT
AQT